1、 Before trial, carefully check whether the cable is damaged, whether the fasteners are loose or detached, and whether the pump is deformed or damaged during transportation, storage and installation.
2、 Use 500V megohm meter to measure the insulation resistance of the pump motor between the same and relative ground, the value is not less than 2 megohm, otherwise the stator winding of the motor should be dried, and the temperature of the drying treatment is not allowed to exceed 120℃.
3, the pump is connected to the direction of rotation from the water inlet for counterclockwise rotation, if the pump is reversed, just any two wires in the cable line to adjust the wiring position.
4. The ground wire of the electric pump must be connected in accordance with the relevant regulations. In order to ensure personal safety when using the electric pump, it is strictly prohibited to arrange the personnel to go into the water when the electric pump is running.
5, the electric pump in no special circumstances must be equipped with automatic pump control, do not hang directly on the grid or gate switch to connect the power supply to ensure the normal operation of the electric pump.
6, the electric pump shall not be a long time in the low head state operation (general use of the head is not less than 60% of the rated head) it is best to control the use of the recommended head range, in order to prevent the electric pump due to overload and burn the motor.
7, no self-circulating cooling device pump is strictly prohibited as a whole exposed to the water surface for long-term operation. In order to prevent the electric pump from overheating and damage.
8、 The pump is equipped with frequency conversion speed control device, which is applicable to a wider range of working conditions.