Submersible slurry pumps of the seven main fault checks and solutions
Submersible slurry pump, as a high-performance pump equipment, is widely used in mining, sewage treatment, sand and gravel plants and other industries. As its working environment is relatively harsh, it is easy to be affected by high concentration of particles, corrosive liquids and other factors, so there may be a variety of failures. The following is the analysis of common failures of submersible slurry pumps and solutions:
1. pump can not start or start difficult
Failure causes:
Power supply problems: low voltage or unstable power supply.
Motor damage: motor winding short circuit or burnt.
Overload protection trigger: the pump load is too large, the current is too high, and the overload protection device starts.
Poor or damaged cable contact: the submersible pump cable is aging, broken or loose joints.
Solution:
Check the power supply voltage to ensure that the voltage meets the motor requirements.
Test the winding of the motor to see if there is a short circuit or broken circuit, if so the motor needs to be replaced.
Check the load of the pump to make sure the pump is working properly, adjust the load or remove blockage.
Check whether the cable is intact, if necessary, replace the damaged cable.
2. No water flow or insufficient water flow after pump startup
Cause of trouble:
Impeller blockage: The pump impeller is blocked by debris or sediment, resulting in insufficient water flow.
Suction pipe blockage: the suction pipe is blocked by foreign matter or the suction port is covered, resulting in restricted water intake.
Poor sealing of pump body: aging or damage of seal ring or mechanical seal, resulting in poor water flow or leakage.
Severe bearing wear: pump bearings are excessively worn, causing the impeller to rotate abnormally and affecting the flow rate.
Solution:
Turn off the pump and inspect the impeller to clear blockages or deposits.
Check whether the suction piping is smooth and clean the debris in the piping.
Check the sealing condition of the pump body and replace the sealing ring or repair the mechanical seal if necessary.
Check the operation of the bearings, if you find serious wear and tear need to replace the bearings.
3. Pump vibration is too large
Fault cause:
Impeller imbalance: there are deposits or damage on the impeller, resulting in imbalance and increased vibration.
Pump shaft bending or deformation: the pump shaft is deformed by external force, resulting in vibration during operation.
The pump is not firmly installed: the pump fixing bracket is loose or not smoothly installed, resulting in abnormal vibration during operation.
Damaged bearing: the bearing is worn or damaged, resulting in abnormal vibration when the pump is running.
Solution:
Check the impeller, remove debris on the impeller or replace the damaged impeller.
Check the pump shaft for deformation or bending, correct or replace if necessary.
Check the installation and fixation of the pump to ensure that the pump body is firmly installed and the bracket is not loose.
Check the bearings and replace worn or damaged bearings in time.
4. Pump seal leakage
Failure causes:
Damaged mechanical seal: prolonged use leads to damage or aging of the mechanical seal, resulting in water leakage.
Poor packing seal: poor packing seal or damaged packing, resulting in slurry leakage.
Pump shaft misalignment: the pump shaft is not centered with the motor shaft, resulting in wear and leakage at the seal.
Solution:
Check the mechanical seal, if the seal is damaged then the seal needs to be replaced.
Check the packing seal, adjust or replace the packing.
Check whether the pump shaft is centered with the motor shaft, and adjust the centering if necessary.
5. Pump overheating
Reason for failure:
Pump Dry Spin: The pump is not fed with water or the amount of water is insufficient, causing the pump to dry spin and overheat.
Motor overload: the pump is overloaded or the motor is working in overload condition, resulting in overheating.
Insufficient cooling: the submersible pump works in the water for a long time, the water temperature is high or the water flow is not smooth, resulting in poor cooling effect.
Solution:
Check the water inlet of the pump to make sure that the water inlet of the pump is not blocked.
Check the load condition of the pump, make sure the working range of the pump is within the rated range to avoid overloading.
Make sure the pump cooling system is normal to prevent the pump from overheating.
6. Unstable pump flow
Cause of malfunction:
Impeller damage: the impeller is worn or damaged, resulting in unstable flow.
Clogged inlet pipe: The inlet pipe or strainer is clogged, resulting in unstable water flow.
Cavitation phenomenon: low inlet pressure or improper operation of the pump may lead to cavitation, affecting the stability of the pump flow.
Solution:
Check the wear of the impeller and replace it if necessary.
Clean the inlet pipe to ensure that the inlet is clear.
Check the inlet pressure of the pump to avoid cavitation and to ensure normal operating conditions of the pump.
7. Pump working efficiency decreases
Cause of failure:
Wear and tear of the pump: prolonged use leads to wear and tear of the impeller, bearings and other parts, reducing the pump’s working efficiency.
Pipe blockage or leakage: Accumulated deposits or leakage in the pipe cause the pump to work less efficiently.
Overuse or overload: the pump has been working under excessive load for a long time, resulting in decreased efficiency.
Solution:
Regularly inspect and replace worn parts, such as impellers and bearings.
Clean pipes and check for blockages or leaks.
Ensure that the pump works within a reasonable load range and avoid overuse.
Summarize.
The common failures of submersible slurry pumps in the process of use are usually related to the wear of the pump body, the damage of the pump shaft, the sealing performance of the pump, and the smoothness of the inlet pipe. Regular inspection, reasonable maintenance and correct use is to extend the service life of the submersible slurry pump, to maintain its efficient operation of the key. For troubleshooting, it can be solved by checking and replacing worn or damaged parts, cleaning the pipeline and maintaining good installation conditions.