1、According to the layout of the device, terrain conditions, water level conditions, operating conditions, economic program comparison and other factors
2, consider the choice of horizontal, vertical and other types (pipeline, right-angle, variable angle, corner, parallel, vertical, vertical, submersible, easy to dismantle, submerged, non-clogging, self-absorption, gear type, oil-filled, water-filled temperature type).
3, according to the nature of the liquid medium, to determine the clear water pump, hot water pumps also oil pumps, chemical pumps or corrosion-resistant pumps or impurity pumps, or the use of non-clogging pumps.
Installed in the explosion area of the pump, should be based on the explosion area level, the use of explosion-proof motor.
4, the amount of vibration is divided into: pneumatic, electric (electric is divided into 220v voltage and 380v voltage).
5、According to the flow size, choose a single suction pump or double suction pump: according to the head height, choose a single suction pump or multiple suction pumps, high speed pumps or low speed pumps (air-conditioning pumps), multi-stage pumps are less efficient than the single-stage pumps, when the elected single-stage pumps and multi-stage pumps can be used, it is preferable to choose a single-stage pump.
6, to determine the specific model of the pump, what series of pumps selected, according to the maximum flow rate, amplify the head after 5% – 10% margin of the two main parameters of performance, in the spectrogram or series of characteristic curves to determine the specific model.
7, the pump model to determine the pump or pumps or transport medium of the physical and chemical medium similar to water pumps, need to go back to the relevant catalogs or samples, according to the model of the performance table or performance curves for the school to see whether the normal operating point falls in the pump priority work area? Effective NPSH is greater than (NPSH). Can also be reversed to NPSH calibration geometric mounting height?
8, for conveying viscosity greater than 20mm2 / s of the liquid pump, be sure to water test pump characteristic curve converted to the viscosity of the performance curve, in particular, such as the performance of the suction to be carefully calculated or more nuclear.
9, to determine the number of pumps and standby rate:
For normal operation of the pump, generally only one, because a large pump and parallel work of two small pumps quite, (refers to the head, flow rate is the same), the pump efficiency is higher than the small pump, so from the point of view of energy saving would rather choose a large pump, but not use two small pumps, but in the case of the following circumstances, you can consider the two pumps in parallel to cooperate:
The flow is very large, a pump can not reach this flow.
For the need to have a 50% standby rate of large pumps, can be changed to two smaller pumps work, two standby (a total of three lifting)
For some large pumps, such as ZJQ submersible slurry pumps, can choose 70% of the flow requirements of the pumps operating in parallel, without standby pumps, in a pump overhaul, the other lift pumps still bear the production of 70% of the delivery.